Induction three-phase electric motors with increased slip

Асинхронные с повышенным скольжениемAiRS.jpg

The motors are designed for drive of mechanisms with high time lag as well as mechanisms, which operate in repeatedly short-time mode (S3). These motors have slip, in case of nominal load, higher than basic motors. Critical slip of these motors is about 40%. It is provided by increasing of rotor winding resistance. The motors are unified with the basic version: the motor have additional letter “S” after series name. The motors are designed to operate with three-phase AC.

  • Network frequency – 50 and 60 Hz
  • Voltage – 220-660 V
  • Protection degree of motor – IP54 (can be manufactured with IP55 on customer’s request)
  • Protection degree of current lead – IP55
  • Insulation class – F.

Technical characteristics in case of 380 V, frequency of 50 Hz

TypeOutput,
 kW
Rotation  
speed,  
rpm
Efficiency,
 %
Cos φ     Мstart
    ——
    Мnom
    Мmax
    ——
    Мnom
    Istart
    ——
    Iном
Average  
noise  
level, dB(A)
Weight,
 kg  
IM 1081
AIRS 80 А21.9300078.00.862.12.26.57012.4
AIRS 80 В22.5300078.00.852.12.26.57315.0
AIRS 90 L23.5300081.00.852.02.26.57319.6
AIRS 80 A41.32150070.00.782.12.25.06311.9
AIRS 80 B41.7150072.00.802.12.25.06313.8
AIRS 90 L42.4150078.00.802.02.26.06718.1
AIRS 80 A60.75100068.00.722.02.14.06011.6
AIRS 80 B61.25100067.50.712.02.14.06015.3
AIRS 90 L61.7100072.00.701.82.26.06019.0
AIRS 80 A80.4575058.00.631.41.73.05713.8
AIRS 80 B80.675061.00.621.41.73.05715.0
AIRS 90 IA80.975070.00.711.41.93.56217.7
AIRS 90 LB81.275068.00.691.51.93.56420.5

The following versions are available:

1) by mounting: 

 - on feet (IM 1081) 

 - with flange (IM 3041, 3641) 

 - combined (IM 2081, 2181) 

- with second free shaft end (IM 1082, 2082, 2182, 3042, 3642) 

- built-in (IM 5010);

2) by climatic conditions: 

Electric motors can be manufactured for all climate regions (including marine, cold, tropical, etc.) on customer’s request.

3) special versions: 

- chemically resistant (Kh2) 

- marine (OM2) 

- with integrated thermal protection (B) 

- with increased accuracy (P).