The motors are designed for drive of mechanisms, which need graduated regulating of rotation speed. The motors are designed to operate with three-phase AC.
Type | Output,
kW | Rotation
speed rpm | Efficiency,
% | Cos φ | Мstart
—— Мnom | Мmax
—— Мnom | Istart
—— Inom | Average
noise level, dB(A) | Weight,
kg IM 1081 |
AIR 80 А4/2 | 1.12/1.5 | 1500/3000 | 74/73 | 0.78/0.86 | 1.9/1.9 | 2.2/2.2 | 5.0/5.0 | 70 | 12.2 |
AIR 80 В4/2 | 1.5/2.0 | 1500/3000 | 75/75 | 0.79/0.86 | 2.0/2.0 | 2.0/2.1 | 5.0/5.0 | 70 | 14.6 |
AIR 90 L4/2 | 2.2/2.65 | 1500/3000 | 79/78 | 0.83/0.86 | 1.9/2.0 | 2.4/2.4 | 6.0/6.0 | 73 | 21.2 |
AIR 90 L6/4 | 1.32/1.6 | 1000/1500 | 74/74 | 0.68/0.85 | 2.3/1.6 | 2.5/2.1 | 5.0/5.5 | 68 | 20.5 |
AIR 90 L8/1 | 0.8/0.32 | 750/1500 | 62/75 | 0.6/0.86 | 1.7/1.5 | 2.0/2.0 | 3.0/5.0 | 63 | 19.3 |
AIR 100 L4/2 | 4.0/4.75 | 1500/3000 | 82/82 | 0.88/0.91 | 1.9/2.2 | 2.1/2.4 | 5.5/6.0 | 73 | 33.0 |
1) by mounting:
- on feet (IM 1081)
- with flange (IM 3041, 3641)
- combined (IM 2081, 2181)
- with second free shaft end (IM 1082, 2082, 2182, 3042, 3642)
- built-in (IM 5010);
2) by climatic conditions:
Electric motors can be manufactured for all climate regions (including marine, cold, tropical, etc.) on customer’s request.
3) special versions:
- chemically resistant (Kh2)
- with integrated thermal protection (B)
- with increased accuracy (P).